MR Imaging of Patients with Stents Is Safe at 7.0 Tesla

Janneke Ansems1, Anja G. van der Kolk2, Hugo Kroeze2, Nico AT van den Berg3, Gert-Jan de Borst4, Peter R. Luijten2, Andrew G. Webb5, W Klaas Jan Renema6, Dennis WJ Klo

1Radboud University Nijmegen Medical Center, Nijmegen, Netherlands; 2Department of Radiology, University Medical Center Utrecht, Utrecht, Netherlands; 3Department of Radiotherapy, University Medical Center Utrecht, Utrecht, Netherlands; 4Department of Vascular Surgery, University Medical Center Utrecht, Utrecht, Netherlands; 5Department of Radiology, C.J. Gorter Center for High Field MRI, Leiden University Medical Center, Leiden, Netherlands; 6Department of Radiology, Radboud University Nijmegen Medical Center, Nijmegen, Netherlands

At increasing magnetic field strength, safety issues regarding RF heating of metallic implants become increasingly important. Although many implants have been tested at lower field strengths, these tests are relatively lacking at (ultra)high field. Based on theoretical assumptions regarding low Q-values, being the dominant factor in tissue heating at (ultra)high field, we tested our theory that scanning metallic implants like stents is RF-safe. Using both experimental Q-value measurements, temperature experiments using commonly used vascular stents scanned at 7.0 Tesla MRI with 3-times SAR-limit, displacement measurements and an in vivo 7T experiment, we show that scanning peripheral stent grafts is RF-safe.

Keywords

acceptance according added administering allowed antenna assess assessment attraction berg beyond breast built capability characterization clear clinical closely coil coils commonly comparable concerning conductive conductivity consent consisted container copper coronary coupling decreased deflection deionized dependence deposition devices diameter dielectric displacement electric electrical embedded energy ensure environment excluded experiment experimental explore fast federal field fields force form frequencies frequency full global grafts hand healthy heating highest hypothesis impedance implant implanted implants in vivo individually induced insulated intrinsic issue lack length limit load loaded local loop magnetically matched materials measured medical metallic mimicking monopole moreover none numerical optic optical optimized parallel particular patients peripheral peter phantoms pickup placed positioned potential potentially power prerequisite probes produced quality radiology radiotherapy ranging recording rectum regarding repetitive resonant resonating restricting rise safe safety scanning significantly simulations since society solution source static steady strength strengths subsequently surrounding system temperature tissue tuned twenty ultrahigh unilateral unloaded upon wavelength whether wire written