Meeting Banner
Abstract #2645

A Compact 10-Channel RF Array Coil for MR Imaging of Mice

Chieh-Wei Chang1, Wen-Yang Chiang1, Steven M. Wright, 12, Mary Preston McDougall1, 2

1Biomedical Engineering, Texas A&M University, College Station, TX, United States; 2Electrical Engineering, Texas A&M University, College Station, TX, United States

Our 10-channel cardiovascular phased array and transmitting volume coil without active detune is presented. Parallel imaging techniques in MRI provide the capability to reduce scan time based on the partial or entire removal of phase-encoding steps, especially offering benefit to cardiovascular MRI of the murine model. Our 10-channel array, transmit coil, and a modular 16-channel low impedance preamplifier board that together constitute a compact parallel imaging of system. The integrated anesthesia chamber provides streamlined imaging capability. The dual plane pair element design [9] described 1) ensures that no coil-to-coil decoupling mechanism is needed other than the preamplifiers and 2) inherently decouples from a homogenous transmit field, eliminating the need for active decoupling and 3) reduces, and in this case, eliminates, the need for baluns and/or cable traps. The transmit coil design described ensures an extremely uniform sensitivity pattern, and the 16-channel preamplifier board described is compact and modularized for straightforward use with any array coil.

Keywords

abstract acknowledge active allows altogether anesthesia animal annual applications around array arrays begun bird birdcage birdcages blue board body bone bottom cable capability cardiac cardiovascular certain changing channel channels circuit clinical coil coils college combines comp compact concentrically connection coupling cylinder decouple decoupled decouples decoupling denotes described design designs ding distance dual edge eight either elem element elements engineering ensured ensures extremely feed field final general goal hardware holder house human impedance implemented indicated inherent initial input inside isolation laboratory lack layout length linear linearly loop made maintaining maps match mechanism meeting mice miniaturization mode mouse need needed network noise outsourced pact pair parallel pare pass pattern place placed position positions preamp preamplifier process profiles quickly radius rather receive recently reconstructed reduces reported represents resonated rigid rung sample scanner semi side sixteen slice space spin square station streamlined switch system together transmit transparency traps trombone tune tuning uniform verified volume yang