Meeting Banner
Abstract #2213

Optimization of the Radial Tagging Profile and Validation Using the Cardiac Atlas Project Database

Zhe Wang1, 2, Abbas N. Moghaddam1, 3, Meral L. Reyhan1, 4, Subashini Srinivasan1, 5, Yutaka Natsuaki6, J.Paul Finn1, 4, Daniel B. Ennis1, 5

1Department of Radiological Sciences, University of California, Los Angeles, CA, United States; 2Biomedical Engineering Interdepartmental Program, University of California , Los Angeles, CA, United States; 3Department of Biomedical Engineering, Amirkabir University of Technology(Tehran Polytechnic), Tehran, Iran; 4Biomedical Physics Interdepartmental Program, University of California, Los Angeles, CA, United States; 5Biomedical Engineering Interdepartmental Program, University of California, Los Angeles, CA, United States; 6Siemens Medical Solutions, Malvern, PA, United States

Due to the gross annular geometry of the left ventricle, a radial tagging sequence may be advantageous for measuring LV contraction and myocardial twist. Radial tagging, in general, requires shifting the patient table away from the iso-center of the main magnetic field to generate a tagging profile that is both sharp and centered at the middle of the LV cavity. In this study we show that >91% of patients can be acceptably imaged with the radial tagging sequence by retrospectively analyzing the short-axis slice position and orientation information from 75 patients in the Cardiac Atlas Project database.

Keywords

acceptable acceptably adjusted advantage annular assess atlas automatic away axes axis basal best biomedical black boundary cardiac cavity clinical components conditions consequence contraction database define defined definition deformation described describes determining encoding encountered engineering ensure evaluation experimentally expressed extracted field finally five frequently function furthermore general generate geometry gradient grid gross hardware head header healthy histogram human ideal identified implemented in vivo interdepartmental linearity magnetization manually matrix measured medical middle minimized minimizes move myocardial nearly need objective optimal optimally optimization orientation orientations parallel part partial pass patient patients pattern patterns percent physics polytechnic position positioned positions practice previously produces profile program project proven pulse pulses qualitatively quality quantify radial radiological radiology read related relies represent requires retrospectively rotating rotation scanner sciences seek segment select settings shaped sharp short sinusoidal slice slices sought spatial subject sufficient supine suppl support table tagging tags technology theory twist updates validation varying vector vectors ventricle view whether worse