Meeting Banner
Abstract #1965

Simple Motion Correction for Hepatic DCE-MRI: Registration of Sequential Breath Holds in 3D Radial Time-Resolved Scans

Eric Bultman1, Debra Horng2, Ethan K. Brodsky2, Kevin M. Johnson2, Walter F. Block1, 2, Scott B. Reeder1, 3

1Biomedical Engineering, University of Wisconsin-Madison, Madison, WI, United States; 2Medical Physics, University of Wisconsin-Madison, Madison, WI, United States; 3Radiology, University of Wisconsin-Madison, Madison, WI, United States

Quantitative perfusion imaging of hypervascular liver lesions performed over multiple breath-holds (BHs) requires compensation for motion between BH periods. In this work, we utilize a contrast-enhanced 3D radial acquisition with 4s true temporal footprint to image the entire abdomen of four healthy volunteers and four patients with hepatocellular carcinoma. We demonstrate that suspension of respiratory motion during sequential BHs produces images free of motion artifact, and that rigid registration of BH-averaged image volumes provides excellent correction for subject motion and variations in residual lung volume between BHs.

Keywords

absolute addition affine anatomy appear approved arterial bellows breath breathing challenge channel chosen club coil compensation completion conduct consistency consistent constraint contrast coordination correction corrections correlate corresponds creates cropped deformation delayed derived descent diaphragmatic difficulty dimension dynamics eight enable enhanced enhancement every expiration footprint foundation frame frames free gaps gating generated gradient healthy hepatic hold holds identification include instructed intervals investigate iterative largest least lesions limitation liver lung magnitude maintaining major many matrix medical metric modeling motion mutual navigators needed negligible none occurs open outside patients perfusion periods permit physics portal position process program quantitative quite radial radiology rapid real reconstructed recorded reeder registered registering registration relatively representative require required requirements resolution respiratory retrospective returned rigid rotation rotations sequential sequentially slices source spatial spherical structures subject subjects subsequently suited support surrounding table temporal torso track traditional transformation translation translations true undergoes unexpected unsigned variations venous volume volumes volunteer waveform waveforms whose