Meeting Banner
Abstract #1388

Imaging of the Osteochondral Interface and Deep Cartilage Using SWIFT

Mikko Johannes Nissi1, Jinjin Zhang1, Djaudat Idiyatullin1, Curtis Corum1, Cathy Carlson2, Ferenc Toth2, Miika Tapio Nieminen3, 4, Jutta Ellermann1

1CMRR - Dept. of Radiology, University of Minnesota, Minneapolis, MN, United States; 2Department of Veterinary Population Medicine, College of Veterinary Medicine, University of Minnesota, Minneapolis, MN, United States; 3Department of Medical Technology, University of Oulu, Oulu, Finland; 4Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland

The involvement of the osteochondral interface in osteoarthritis is known, but perhaps less appreciated than warranted. Recent developments in ultrashort/zero-echo time imaging methods have enabled the MRI investigation of calcified and subchondral structures. In uTE studies, the bright line at the cartilage-bone interface has been associated with calcified layer of cartilage and deep layers of cartilage. In the present study, SWIFT was utilized to further study the origin of this feature. The results confirmed the earlier findings but also pointed to a possible contribution of signal pileup due to susceptibility differences between cartilage and bone or calcified cartilage.

Keywords

acknowledge acknowledgments addition appearance appreciation approximately assessment authors background bandwidth beginning bone bright bristol built calcified cartilage characterization clear coil college combination complex console contribute deep deepest degree degrees dependence dept developments dislocated emphasized enabled essentially evaluated exceeds excitation exhibit existence faintly feature foundation fraction frequency full generally glass grants histological histology home horizontal hospital immersed include incomplete indicates indicative inside interface interleaved invariably investigate investigation involvement known layer layers loop magic magnet matrix maturation measured medial medical medicine micrometers month nominal offset orientation orientations oriented origin osteoarthritis parallel perhaps perpendicular physiological pixels placed pool population porcine positioned prepared preserved preserving prior processed programs properties proton radiology receive recent reconstructed repeated reported resolution reveal room saline sample samples saturated saturation scale schemes short solution spokes staining structures studies subtracting subtraction superimposed susceptibility swift take technology temperature timing tissue transmit tuned ultrashort utilized utilizing veterinary vial view virtually visible warranted yielding zero