Meeting Banner
Abstract #1362

Assessment of Liver Fat with T2 Correction Using Magnetic Resonance Spectroscopic Imaging

MAGNA25Jian-Jia Chiu1, Yi-Ru Lin1, Shang-Yueh Tsai2, 3

1Department of Electronic Engineering, National Taiwan University of Science and Technology, Taipei, Taiwan; 2Graduate Institute of Applied Physics, National Chengchi University, Taipei, Taiwan; 3Reasearch Center for Mind, Brain and Learning, National Chengchi University, Taipei, Taiwan

Early detection of non-alcoholic fatty liver disease can prevent further complications such as steatohepatitis, fibrosis and cirrhosis. Previous we have shown that proton echo planar spectroscopic imaging (PEPSI) is able to detect spatial distribution of liver fat content. Here we further investigated the influence of T2 relaxation effects. Non-water suppressed liver spectra were obtained using PEPSI sequence. PEPSI scans were repeated 8 times to observe the reproducibility of T2 correction. Our results showed that hepatic fat content distribution with T2 correction can be achieved in less than 3 minutes with our protocol. And the measured fat content is highly reproducible.

Keywords

abdominal able according accuracy accurate achieved acquisition addition alcoholic among anatomic applied around array assessment becomes better body boundary brain breath carried chosen cirrhosis coil complications computed consider content contents corrected correction crucial curve decades decreased defined detect detected detection deviation disease diseases distribution early electronic engineering errors even exclude experiment exponential extend extrapolating fast fatty fibrosis finished fitted fitting function graduate hepatic hepatitis include included increasing index indicating influence institute instructed intensity investigate known learning lipid listed liver localization longer male manually maps mass matrix measured methylene mind minutes national observe obvious overestimation participated peaks physics planar plot position potential preliminary prevalence prevent previous process progressively protocol proton quantification quantified ranging recent reconstruction regular reliability reliable report representative reproducibility reproducible resolution selected shortest slice spatial spectra spectroscopic spectroscopy spectrum spine steps still subcutaneous subject subjects successfully supine suppressed surface table technology tomography ultrasound uncorrected useful variation varied water wide world