Meeting Banner
Abstract #1303

Introduction and Evaluation of Different Approaches for the (Semi-)quantitative Assessment of Renal Sodium Content with 23Na MR Imaging

Stefan Haneder1, Simon Konstandin2, John Morelli3, Lothar R. Schad2, Stefan O. Schoenberg1, Henrik J. Michaely1

1Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, Mannheim, Baden-Wrttemberg, Germany; 2Computer Assisted Clinical Medicine, Heidelberg University, Mannheim, Baden-Wrttemberg, Germany; 3Scott and White Memorial Hospital and Clinic Texas A&M University Health Sciences Center, Temple, TX, United States

Two new approaches are introduced and evaluated for the (semi-)quantitative assessment of the renal sodium content with 23Na MR imaging before and after a water load. One approach used the cerebrospinal fluid as internal reference for the cortico-medullary 23Na gradient. The second approach quantified the cortico-medullary 23Na gradient with reduced numbers of slices. Both methods are compared to the gold standard quantification with complete data sets and external references. Both approaches showed non-significant differences compared to the gold standard and seem to be a feasible and faster alternative for potential clinical application.

Keywords

absolute abstain accuracy acquisition adapted adjacent approaches approval artifacts assess assessment assessments assisted available baden beside body central clinic clinical coil commercially computer concentration conditions consists content correlated cortex covered covering cumbersome decrease decreased decreases density dilutions dorsally elements especially evaluated evaluation every external faster feasibility feasible field find fluid functional gold gradient gradients halves health healthy hospital human identical immediate implementation in vivo included incorporated instead institute institutional intact internal introduced isotropic kidney kidneys known length linear load located loop magnitude mainly maps mathematically measure medical medicine medulla memorial nuclear oral paired panel past phantoms pixel potential projections prone qualitative quantification quantified quantitative radiology rapid readout receive reduced reduction renal representative reproduce resolution scanner scenario scenarios scheme sciences sector semi serving several significantly simple simplify simplifying slice slices sodium sophisticated spatial spoke statistically studies successfully technically temple trajectory transmit tuned upper utilized utilizing various ventrally view visible volunteer water whereby whole years