Quiescent-Interval Single-Shot Non-Contrast Enhanced MR Angiography Using Two-Point Dixon Fat-Water Decomposition

Daniel V. Litwiller1, Mahdi S. Rahimi2, Wei Sun3, Ananth J. Madhuranthakam4, Dan W. Rettmann1, Frank R. Korosec5, Jean H. Brittain6

1Global Applied Science Laboratory, GE Healthcare, Rochester, MN, United States; 2Biomedical Engineering, University of Wisconsin, Madison, WI, United States; 3MR Engineering, GE Healthcare, Waukesha, WI, United States; 4Global Applied Science Laboratory, GE Healthcare, Boston, MA, United States; 5Medical Physics and Radiology, University of Wisconsin, Madison, WI, United States; 6Global Applied Science Laboratory, GE Healthcare, Madison, WI, United States

Quiscent-Interval Single-Shot (QISS) is a recently developed non-constrast MR angiography technique that relies on a signal-saturation-based fat suppression pulse, which is sensitive to B0 and B1 inhomogeneities. In this work, we report a dual-echo bipolar QISS sequence, followed by a two-point Dixon fat-water reconstruction algorithm to synthesize fat-free, water-only images of arterial signal in the lower extremities, demonstrating robust and uniform fat suppression, improved vessel conspicuity and increased signal-to-noise ratio.

Keywords

abdomen accelerated acquisition acquisitions added addition additional alternative amount anatomic angiography application applied approximately arterial background balanced bandwidth beneficial benefit biomedical bipolar cardiac challenging channel chosen coil compatible complete consent consistency contain contains continues contrast coronal coverage decomposition delay developed diagnostic diastolic digital double dual engineering enhanced enhancement ensure equal establish evaluating exhibit extremities feasibility flow frank free gated global healthy identical improved incorporating informed inhomogeneities initial intensity interpolation interval invasive jean knee laboratory lead limb linear materials matrix maximal medical modified nature nearly note obscured optimization otherwise overlap padded parallel partial patients pelvis performance period perturbation physics planning positioned preceded precession preparation previously projection proposed prove pulse quiescent radiology receive recently reconstruction reformat registered reported resolution respectively reveals robust saturation scanner science selective separation sets shot slice slow spatial steady strategies subcutaneous suppression surgical symptomatic synthesize synthesized timing twice uniform useful utilizes venous vessel vessels visualization volunteer water yields zero