Motion-Induced Dark-Rim Artifact in First-Pass Myocardial Perfusion MR: A Controlled Canine Study

Behzad Sharif1, Rohan Dharmakumar1, Louise Thomson2, Noel Bairey Merz2, Daniel S. Berman2, Debiao Li1

1Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, and University of California Los Angeles, Los Angeles, CA, United States; 2Heart Institute, Cedars-Sinai Medical Center, Los Angeles, CA, United States

A major limiting factor for specificity and sensitivity of current MP MR methods is the so-called subendocardial dark-rim artifact (DRA), which may mimic perfusion deficits. It is known that DRAs in conventional Cartesian imaging protocols are caused by a combination of factors including Gibbs ringing and cardiac motion effects. In this work, we aimed at improving the analysis of motion-induced DRAs by considering the combined effect of cardiac motion and limited spatial resolution (Gibbs ringing) on both the spatial extent and temporal persistence of the DRA. We performed first-pass MP MR on healthy dogs at moderate to high heart-rates to evaluate the effect of motion on the DRAs in terms of their spatial extent and temporal persistence. In addition, we present initial results for an alternative highly-accelerated radial acquisition and reconstruction scheme that can potentially eliminate the DRA due to motion.

Keywords

accelerated acquisition addition additional administered affects afterwards aimed allow almost alternative anesthesia animals appear approval arrhythmia arrows artifact biomedical blurring bolus breath building called canine cardiac care caused cedars clinical combination combined committee comparing compressed concluded consecutive considering contains contrast controlled convolution correspond dark deficit deficits degrees denote depends described detection dogs domain dose early edges eliminate enhancement epinephrine evaluation example extent finally flash frame frames function gadolinium healthy heart highlighted highly impede improving in vivo induced initial institute institutional interleaved intrinsic invasive known last limited limiting mainly matches matrix medical mimic minute moderate motion moving myocardial narrower nature next numerical oscillating oxygen panel parallel pass perfusion persistence phantom potential potentially prepared product prominent protocols radial readout reconstructed reconstruction representation resolution resolutions respectively respirator resting ringing robustness rows scanned scanner scheme sensing sensitivity sharp shot significantly simulation solution spatial specificity started steps temporal temporally theory true underlying ventilated ventricular wait wash wider window