Meeting Banner
Abstract #1089

3D Neuromelanin-Sensitive MRI with Automated Volume Measurement of Substantial Nigra Pars Compacta for the Diagnosis of Parkinson's Disease

Kimihiro Ogisu1, Kosuke Kudo2, Makoto Sasaki2, Ken Sakushima3, Satoshi Terae4, Mitsuhiro Nakanishi, Shunrou Fujiwara5, Hiroki Shirato1

1Graduate School of Medicine, Hokkaido University, Sapporo, Hokkaido, Japan; 2Advanced Medical Research Center, Iwate Medical University; 3Department of Neurology, Hokkaido University Hospital; 4Department of Radiology, Hokkaido University Hospital; 5Department of Neurosurgery, Iwate Medical University

Neuromelanin-sensitive MRI has been reported for the diagnosis of Parkinson's disease (PD). However, previous reports used 2D fast spin echo sequence with subjective measurement of the substantia nigra pars compacta (SNc). We developed 3D gradient echo technique of neuromelanin-sensitive MRI. The volume of SNc was automatically measured and was significantly smaller in PD patients than in healthy volunteers. Although sensitivity and specificity were not high enough compared to the previous reports, 3D neuromelanin-sensitive MRI with automated volume measurement was feasible, and could objectively distinguish PD patients from healthy volunteers.

Keywords

accumulation achieved acquisition advanced affects analyzer assumed automated automatically best black brain called cerebellar characteristic clinical contain cutoff define defined degeneration depends detecting determine diagnose diagnosis diagnostics difficult disease disorder disorders distinguish examined excite excluding fast feasibility ferrous field findings gradient graduate growing healthy hospital illness improve indicating inhomogeneity intensity japan limited locus magnetization mainly matched materials matrix measured medical medicine might mismatch modified needed neurology neurons neurosurgery normalizing objective objectively operating optimal optimizations optimum paramagnetic pars partial patients peduncle perfusion period pigment previous previously probably protocol psychiatry pulse radiology rating reached receiver recorded repetition reported reports respectively role satisfactory scale school seeding sensitive sensitivity shortening significantly slice slices smaller specificity spin stability stage statistical statistics student studies subjective substantial suggests suitable superior technology thanks threshold thresholds transfer unit various version versus view volume volumes volunteers years