Fast High Resolution Imaging of the Mouse Brain Using a Cryogenic 2x2 Phased Array Coil at 9.4T

Aline Seuwen1, Daniel Marek2, Stefan Zwick2, Aileen Schrter3, Markus Rudin3, 4

1Institute for Biomedical Engineering, University and ETH , Zrich, Switzerland; 2Bruker BioSpin AG, Fllanden, Switzerland; 3Institute for Biomedical Engineering, University and ETH, Zrich, Switzerland; 4Institute of pharmacology and toxicology, University of Zrich, Switzerland

First in vivo results of a four-element receive-only cryogenic phased array surface coil operating at 30K (2x2 geometry, overall coil size 20x27mm2) are presented. The coil system was used in combination with a room temperature volume resonator for transmission. FLASH and RARE sequences were applied for fast 2D and 3D high-resolution imaging. The phased array design allows accelerated data acquisition using parallel imaging strategies. Furthermore, the high sensitivity and uniform excitation enable whole brain imaging with high resolution. The setup is also attractive for functional MRI and spectroscopic imaging, which critically depend on high SNR values.

Keywords

abstract accelerated accelerating acceleration acquisition adherence advantages allows anesthetized animal annual appear application applying array artificially attractive axial basic biomedical brain carried choroid coil coils combination combined conditions confronted coronal correspondingly coupling critically cross cryogenic dark dataset decoupling deep deeply delicate depend design disturbed electronics element elements enabling engineering entering evaluated excellent excitation fast field fine flash functional functionality gain gains geometry good illustrated improving in vivo individual inherent institute intubated invested linear linearly lobes located lying made matrix meeting mice mixture mode moreover mouse operating oxygen parallel particular performance phantom pharmacology plexus polarized potential presence probe processed profiles progress protection providing quadrature rare readily realize receive receiver recently reconstruction recorded reducing reported resolution revealed rich room scientific section sections sense sensitivity serves setup slice spatial spectroscopic spinal squares stem strategies strict structural structures superior surface system technology temperature together toxicology tracts transmission transmit turbo uniform usability ventilated ventricles views visualizing volume whole