A 64-Channel Receive-Only Field Camera for Eddy Current & Trajectory Calibration

MAGNA25Veneta Tountcheva1, Boris Keil2, Thomas Witzel1, Dylan Tisdall2, Philipp Hoecht3, Lawrence L. Wald1, 4

1A.A. Martinos Center for Biomedical Imaging, MGH, Harvard Medical School, Radiology, Charlsetown, MA, United States; 2A.A. Martinos Center for Biomedical Imaging,, MGH, Harvard Medical School, Radiology, Charlsetown, MA, United States; 3Siemens Medical Solutions USA Inc., Charlsetown, MA, United States; 4Harvard-MIT, Div. of Health Science and Technology, Cambridge, MA, United States

64ch receive-only field camera has been built to study the spatial and temporal evolution of the magnetic field in the presence of eddy currents and gradient trajectories. The field camera consists of 64 small solenoids in a 4 x 4 x 4 grid, each with a small (0.9mm diameter) water sample in a capillary plugged with susceptibility matched material. The camera was validated with field maps acquired after inducing eddy currents on the x-, y-, z-gradients at different time delays. The eddy currents frequency offsets have been mapped out as a function of position and time delay for each x-, y-, z-gradients allowing determination of the eddy current gradients and gradient cross terms time constants and amplitudes for either pre-emphasis adjustment or inclusion in image reconstruction methods.

Keywords

absence academic accumulated acquisition active actuators additional allows amplitude angular applied applying array assuming availability avoid away axis bandwidth become blurring body building cable calibration camera capillary cause challenges channel characterization characterized chosen circuit circuitry close coax coil coils compensation consists construct constructed copper correct creating decoupling delay determined detuning diameter diffusion distortions dynamics eddy edge falling field fields forms free frequency full goal gradient gradients grid hard head health holders housing human impedance imperfect improve induced input insoluble internal interval isolation knowing length lifetime limiting long magnetically maps matched matching measure measured medical mismatch monitoring needed negative novel oriented perpendicular plugged position positioned positions positive probe probes project providing pulse quarter quick quickly radiology ramp ramping readout receive reconstruction residuals resolution sample scale scanner school science sensors shifter shim since slowly solenoid spatial step strength susceptibility tightly trajectory transmit tray tuning turn typical validate vulnerable water windings wire wound zero