Meeting Banner
Abstract #0478

Hyperpolarized Water as an MRI Contrast Agent: Feasibility of in vivo Imaging in a Rat Model

SUMMA25Mark David Lingwood1, 2, Ting Ann Siaw3, Napapon Sailasuta4, Osama A. Abulseoud5, Henry R. Chan4, Brian D. Ross4, Pratip Bhattacharya4, Songi Han1, 3

1Department of Chemistry and Biochemistry, University of California, Santa Barbara, Santa Barbara, CA, United States; 2Department of Chemistry, Virginia Polytechnic Institute and State University, Blacksburg, VA, United States; 3Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, United States; 4Enhanced Magnetic Resonance Laboratory, Huntington Medical Research Institutes, Pasadena, CA, United States; 5Department of Psychiatry and Psychology, Mayo Clinic, Rochester, MN, United States

In this presentation we demonstrate a new perfusion MRI technique that utilizes Overhauser dynamic nuclear polarization (DNP) to provide authentic image contrast through the continuous delivery of contrast agent-free hyperpolarized water in rats. Water is hyperpolarized via Overhauser DNP at room temperature in the 0.35 T fringe field of a 1.5 T MRI magnet and then quickly transferred to the subject in the center of the same magnet for imaging. Images with hyperpolarized water show clearly enhanced flow contrast for all injection locations, demonstrating that this technique holds promise for localized angiography or brain perfusion studies.

Keywords

ability according acquisition addition agent agents anesthetized angiography aorta application approved arrow arteries artery axial biochemistry biomedical brain built bulk capable care carotid catheter causing certain challenges chemical chemistry classes clearly clinic clinical color comes committees continuous continuously contraindications contrast creates custom decrease deliver demonstration developed diluted dissolution engineering enhance enhanced enhancement enters exploratory feasibility femoral field flow free fringe gadolinium gradient greater hemisphere henry human important improvements in vivo infusing inherently injected injecting injection injections inside institute institutes institutional intensity inverted laboratory lateral length live local localized magnet making many mark materials mayo medical model models modification monitor necessary need negative noted nuclear operating panel passes patients perfusion phantoms physical placing polarization positive potential practice prepared previously problems process processed properties protocols providing psychiatry psychology pure radical rats reduction rely room safe sensitivity several solely specially still subcutaneous subject substance suited system temperature trajectory tubing utilizes ventricles visualized volume water ways wide