Meeting Banner
Abstract #0283

Multiparametric MRI Assessment of Early Osteoarthritis in a Rabbit Model of Anterior Cruciate Ligament Transection

MAGNA25Jari Rautiainen1, Mikko J. Nissi1, 2, Timo Liimatainen3, Walter Herzog4, Rami K. Korhonen1, Miika T. Nieminen5, 6

1Department of Applied Physics, University of Eastern Finland, Kuopio, Finland; 2Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States; 3Department of Neurobiology, A.I. Virtanen Institute for Molecular Medicine, University of Eastern Finland, Kuopio, Finland; 4Faculty of Kinesiology, Engineering and Medicine, University of Calgary, Calgary, AB, Canada; 5Department of Diagnostic Radiology, Oulu University Hospital, Oulu, Finland; 6Department of Medical Technology, University of Oulu, Oulu, Finland

The sensitivity of selected quantitative MRI parameters (Adiabatic T1ρ & T2ρ, continuous wave (CW) T1ρ, CPMG T2, Adiabatic double echo (DE) T2, T1 during off-resonance saturation, and relaxation along fictitious field (RAFF)) to early OA changes in rabbit anterior cruciate ligament transection model was investigated. Biomechanical testing of the samples revealed altered functional properties of the tissue in response to experimental OA, and a differential response to the various MRI methods was observed. Relaxation in the rotating frame of reference (continuous wave and adiabatic T1ρ and adiabatic T2ρ) proved to be most sensitive in detecting early cartilage degeneration.

Keywords

according adiabatic affected altered animal anterior appeared applied approved articular assessment biomedical block care carried cartilage characteristic collagen committee common compartment compartments concordance console content continuous control correlation council course deep degeneration degradation detected detecting detection determination determined diagnostic differentiating double duration dynamic early eastern elastic elongation embedded encourages ended equilibrium ethics experimental extracellular fast femoral fictitious field findings frequency full furthermore global harvested healthy highest implementation indentation injury inside integrity investigate investigation irradiation joint joints lateral length ligament load magnetization maps matrix mature measured mechanical medial medical medicine model modulus molecular moreover mostly nelson offset osteoarthritis oxford period physics positioned post preparation previous procedure promoting properties pulse pulses quadrature rabbit rabbits rapid readout reduced reliable reporting respectively rotating samples saturation selected sensitive sensitivity sides significantly sinusoidal site slice slices slight slow spin statistical stepwise stress strongly superficial superior surface table technology thereby train transceiver transected traumatic wave weeks white wide