Meeting Banner
Abstract #0262

Intravoxel Incoherent Motion Diffusion-Weighted Imaging for Detection of Liver Fibrosis in HCV: Comparison of Four Sequences

Hadrien Arezki Dyvorne1, Thomas Nevers1, Nicola Galea2, M. Isabel Fiel3, David Carpenter1, Edmund Wong1, Matthew Orton4, Andre de Oliveira5, Marie-Louise Vachon3, Manjil Chatterji1, Douglas Dieterich3, Bachir Taouli1

1Radiology, Mount Sinai School of Medicine, New York, United States; 2Sapienza University, Rome, Italy; 3Department of Medicine/Liver Disease, Mount Sinai School of Medicine, New York, United States; 4CR-UK and EPSRC Cancer Imaging Centre, Institute of Cancer Research, Sutton, Surrey, United Kingdom; 5AG Healthcare Sector, Siemens, Erlangen, Germany

This study compares the performance and reproducibility of four diffusion-weighted sequences using multiple b values and biexponential fit for the detection of liver fibrosis in chronic hepatitis C. We investigated the role of gradient polarity and respiratory monitoring on the reproducibility and diagnostic quality of IVIM parameters. For all sequences, results showed acceptable to excellent reproducibility and a marked decrease of diffusion, perfusion fraction and apparent diffusion coefficients with the degree of fibrosis. In addition, free breathing acquisitions were found to give the better results.

Keywords

able acceptable account acquisition addition additionally aims antiviral apparent approved assess assessment best biopsy bipolar blood breathing cancer carpenter chronic cirrhosis clinical coefficient collagen combined consecutive consented coronal cycle decay decrease decreased deposition detecting detection diagnosed diagnosis diagnostic differentiate differs diffusion disease distribution drawn encoding especially evaluate exams excellent except excessive exponential fibrosis fitting fraction free generally give goal good gradients grant healthy hepatitis impaired incoherent infection institute interleaved invasive kingdom larger liver longitudinal medicine microscopic mono motion mount needed needs paired patients performance perfusion poorly population portal preliminary previous promise promising prospective pseudo radiology reported reproducibility reproducible resolution respiratory restrict sampled scheme schemes school scores sector significantly sinusoids slices spanning stages studies subjects supported suppressed surrey table tends terms therapy tissue tool trend triggered true underwent urgent vary vascular vein virus volume water weeks yielded