Abstract #0110

Combined IVIM & DTI for Simultaneous Assessment of Diffusion & Flow Anisotropy of the Kidney

MAGNA25Mike Notohamiprodjo1, 2, Hersh Chandarana3, Artem Mikheev2, Jose Garcia Raya2, John Grinstead4, Thorsten Feiweier4, Henry Rusinek3, Vivian S. Lee, 35, Eric E. Sigmund2

1Department of Clinical Radiology, University Hospitals Munich, Munich, Bavaria, Germany; 2Center for Biomedical Imaging, NYU Langone Medical Center, New York City, NY, United States; 3Department of Radiology, NYU Langone Medical Center; 4Siemens Healthcare; 5University of Utah Health Care

We used a combined IVIM-DTI methodology to resolve the ambiguity of renal diffusion anisotropy by distinguishing structural from flow effects. We observe a significantly higher perfusion-fraction (fp) of the cortex than medulla, contrary to previous studies finding comparable fp in both tissues. Higher medullary FA at the low b-value range and high directional variance of medullary fp suggest anisotropy of the perfusion-fraction. Similarly, both flow and diffusion appear to contribute to the diffusion anisotropy of the renal medulla. This novel method may be useful in separating decreased tubular flow from irreversible structural tubular damage, e.g. in diabetic nephropathy.

Keywords

acquisition affine ambiguity angular anisotropies anisotropy another application axial bins biomedical biophysical black blue breathing care city clear clinical collecting combined comparable compelling comprehensive constrained contribute correction cortex cortical custom damage decreased depicts derived described determine determined deviation diabetic diffusion diffusivity directional distinguish distinguishes distribution drawn ducts effective eigenvector eigenvectors evaluation examined feasible finally finding findings flow fraction fractional free full function global health healthy henry hospitals incoherent indicates intercept invest investigate irreversible isotropic kidney manually maps material measured medical medulla methodology mike mitigate molecular motion nearly novel oriented paired particularly passive peanut perfusion perpendicular planar plot plotted primary protocol radial radiology reflecting refocused regarding regimes registration rejection renal representation resolving respiratory restriction retrospective scanner scatter segmented segmenting separating several significantly simultaneous slice software spin statistical step strong structural structures studies subject suggest summarizes table tensor tissue tissues tubular tubules twice underpinning unproven useful variance variants vascular visualized volunteers weightings zero